12-Volt Negative Ground Installation Instructions
Page 1 of 4
CAUTION!!! Before installing, please read the following important information....
909-599-5955 www.pertronix.com
12-Volt Negative Ground Installation Instructions
Page 1 of 4
CAUTION!!! Before installing, please read the following important information....
909-599-5955 www.pertronix.com
1. The Ignitor is designed for 12-Volt negative ground systems.
2. Leaving the ignition “ON” with the engine “OFF” for an extended period could result in permanent damage to
the Ignitor.
3. See Chart on back page for coil recommendations.
4. Eight cylinder engines require a minimum of 1.5 ohms of primary resistance. Do not remove resistors if the
coil primary resistance is less than 1.5 ohms.
5. If your Ignition coil has the recommended primary resistance, remove or bypass all external resistors.
6. The Ignitor is compatible as a trigger for most electronic boxes.
12-Volt Negative Ground Installation Instructions
Page 1 of 4
For Part Number: ML-189
DISASSEMBLY
1. PRIOR TO INSTALLATION TURN IGNITION SWITCH OFF OR DISCONNECT THE BATTERY
2. Remove distributor cap and rotor from distributor. Do not disconnect spark plug wires from cap. Examine cap
and rotor for wear or damage. Replace as needed.
3. Remove the points wire from the (-) terminal of the Ignition coil.
4. Remove and retain the points and condenser. Installing the Ignitor does not alter the internal configuration of
your distributor. Therefore, the points, condenser and hardware can be used as backup.
5. Clean all dirt and excess oil from the point cam.
IGNITOR INSTALLATION
1. Install the Ignitor into the distributor housing, align the Ignitor to the breaker plate as shown in figure 1.
Fasten the plate into place using the original screws.
2. Install magnet sleeve over the distributor shaft, onto point cam. Rotate the sleeve until a slight locating
position is felt before applying pressure. Press down firmly insuring sleeve is fully seated.
3. Module and magnet sleeve air gap is not adjustable.
4. Insert wires through the wire exit hole in distributor housing. Pull the rubber grommet into place. Make sure
wires do not interfere with any moving parts.
5. Reinstall the rotor, and the distributor cap. Make sure all spark plug wires are securely attached.
6. See Wiring Instructions.
FIGURE 1
Wire exit hole.
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - For Part Number: ML-189

12-Volt Negative Ground Installation InstructionsPage 1 of 4CAUTION!!! Before installing, please read the following important information...909-599-5

Seite 2 - (FIGURE B)

COIL WIRERED WIREBLACK WIRETO IGNITION COIL WIRETO IGNITION SWITCHRED WIREBLACK WIRERESISTANCE WIREBALLAST RESISTORThe Ignitor can also be installed i

Seite 3 - POWER & GROUND TESTS

Q. What is the first thing I should check if the engine would not start? A. Make certain all wires are connected securely to the proper terminals.Q. T

Seite 4 - Page 4 of 4

LIMITED WARRANTY Pertronix, Inc. Warrants to the original Purchaser of its solid-state ignition system (product) that the Ignitor, magnet assembly an

Kommentare zu diesen Handbüchern